Time Protocols
SNTP: Viewing, Selecting, and Configuring
Figure 8-6. Example of Specifying the SNTP Protocol Version Number
8-12
Changing the SNTP Poll Interval. This command lets you specify how
long the switch waits between time polling intervals. The default is 720
seconds and the range is 30 to 720 seconds. (This parameter is separate from
the poll interval parameter used for Timep operation.)
sntp poll-interval <30 . . 720>
Syntax:
For example, to change the poll interval to 300 seconds:
HPswitch(config)# sntp poll-interval 300
Disabling Time Synchronization Without Changing the SNTP
Configuration. The recommended method for disabling time synchroniza-
tion is to use the
timesync
changing your SNTP configuration.
Syntax:
no timesync
For example, suppose SNTP is running as the switch's time synchronization
protocol, with
Broadcast
interval. You would halt time synchronization with this command:
HPswitch(config)# no timesync
If you then viewed the SNTP configuration, you would see the following:
Figure 8-7. Example of SNTP with Time Sychronization Disabled
command. This halts time synchronization without
as the SNTP mode and the factory-default polling
Deletes unicast SNTP server entry.
Re-enters the unicast server with a non-
default protocol version.
show sntp displays the result.