6 Bluetooth™ Communications
The printer control card communicates with the Bluetooth™ base band interface at 38,4 K Baud/sec for serial interface
printers using no parity. To select the Bluetooth™ interface, Dip Switch # 6 must be ON and all other Dip Switches must
be OFF. If required by the host application to enter 0 (digit zero) for PIN number while connecting to the BT module.
Bluetooth settings can be changed via the AT command set (Refer to 2000i_Bluetooth Addendum on Dev. CD).
The table below details the Bluetooth default settings:
Settings
Name
Serial Settings
Discoverability mode
Connectivity mode
Security mode
Fixed PIN
Set Master/Slave Policy
Client Profile
Server Profile
Wireless Multi-drop mode
Configuration over Bluetooth
Power Save mode
ESC sequence timing
Value
Datamax-O'Neil Printer
38,400,8,n,2,n
Generally Discoverable
GAP Connectable
Security Disabled
0 (Zero)
Always let the connecting device select the master/slave role on
incoming connections
Disable Client Services
Serial Port Profile Server enabled
disabled, forward to host only
Enabled
Allow Sleep mode only
500ms before ESC command & 500ms thereafter
13