Rs232 Communication Interface - General Notes & Dip Switch Settings - Datamax S2000i User Manual

Table of Contents

Advertisement

5.3 RS232 Communication Interface - General Notes & DIP Switch
Settings
Eight-position dip switch, located to one side of the paper roll, is used to select and set the serial RS232
interface. The printer reads these switches once, on initial power-up. The functions assigned to each
switch are listed in Table 2.
Proper Baud Rate and protocol settings are required to communicate with a host computer. The standard
factory setting is 19,200 BAUD, 8 DATA BITS, NO PARITY BIT, and one STOP BIT, all switches in
off position.
Dip Switch
1 & 2
3
4 & 5
6
7
8
FIGURE 4 – Serial Connector
TABLE 2 - DIP switch settings
Function
Baud rate
Standard Baud rate
38,400
19,200
9,600
4,800
No. of data bits
7 Data Bits
8 Data bits
Parity bit
Serial RS232 mode
No Parity
Odd Parity
No Parity
Even Parity
Bluetooth Communication
Enable
Disable
Reserved
Communication Interface
RS232
10
SW1
SW2
Off
Off
On
Off
Off
On
On
On
SW3
on
Off
SW4
SW5
off
off
on
off
Off
0n
on
on
SW6
On
Off
SW7
Reserved
SW8
Off