Automatic Temperature Control
To avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless
testing requires it.
ATC Connector
Terminals
RED
1
2
VIOLET
YELLOW
3
BLUE
4
To properly test ATC thermostats follow the steps below:
*IMPORTANT: To protect meter all continuity checks must be made on the connector end going to thermostats.
Step 1. Disconnect 4-wire plug connector located in blackguard coming from water flume thermostats.
Step 2. Set water temperature selection for cold water fill and allow washer to fill for 2 minutes. Confirm water
temperature entering washer is < 60 degrees and make continuity checks per table.
Step 3. Set water temperature selection for hot water fill and allow washer to fill for 2 minutes. Confirm water
temperature entering washer is > 110 degrees and make continuity checks per table.
Step 4. If results of continuity checks do not correspond to table and all wiring is correct, replace ATC flume
thermostat.
©2005 Maytag Services
!
Water temperature
Wire Color
<60 degrees
RD to VT
<60 degrees
BU to YL
>110 degrees
RD to VT
>110 degrees
BU to YL
Screw is located under Control
Panel on the Cabinet Top
16022937 Rev. 0
WARNING
Circuit
open
closed
closed
open