Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or electrical shock.
CAPACITOR
Refer to page 5-4 for the procedure for servic-
ing the capacitor.
1. Unplug the clothes vitalizer or disconnect
the power.
2. Set the ohmmeter to the R x 100 scale.
3. Disconnect one of the wires from the ca-
pacitor terminals.
4. Touch the ohmmeter test leads to the ca-
pacitor terminals. The meter should drop
toward zero and then gradually return to-
ward infinity.
WARNING
Electrical Shock Hazard
BUZZER
Refer to page 5-4 for the procedure for servic-
ing the buzzer.
1. Unplug the clothes vitalizer or disconnect
the power.
2. Set the ohmmeter to the R x 1 scale.
3. Disconnect one of the wires from the
buzzer terminals.
4. Touch the ohmmeter test leads to the
buzzer terminals. The meter should indi-
cate approximately 700 to 1100 Ω.
6-2