Removing The Compressor - Whirlpool Personal Valet PVBN600 Service Manual

Clothes vitalizing system
Hide thumbs Also See for Personal Valet PVBN600:
Table of Contents

Advertisement

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Unplug the clothes vitalizer or disconnect
the power.
2.
Remove the twelve T-15 Torx screws from
the top component cover and remove the
cover from the unit (see page 5-2).
The component described on this page is
shown below.
3.
Disconnect the 2-wire power connector
from the wiring harness (see the photo to
the right).
4.
Disconnect the orange wire from the ca-
pacitor terminal.
5.
Remove the mounting screw from the
green ground wire.

REMOVING THE COMPRESSOR

Compressor
6.
Mark the top hose of the compressor with
pieces of tape, or use a marker, for iden-
tification.
7.
Cut the two hose clamps and pull the
hoses off the compressor fittings.
8.
Loosen the four T-15 Torx mounting
screws.
9.
Slide the compressor brackets so the large
openings in the two keyhole slots are over
the screw heads, and remove the com-
pressor.
Bottom Hose Clamp
Orange Capacitor Wire
Green Ground Wire
2-Wire Power Connector
WARNING
Electrical Shock Hazard
Connect green ground wire to ground
screw.
Failure to do so can result in death or
electrical shock.
5-3
Top Hose Clamp
Compressor
Torx Screw (1 of 4)