Top
Spacers
Left
Side
Front
Pebble Pan
OPERATION
This vent-free fireplace is clean burning. It
requires no outside venting. There is no heat
loss out a vent or up a chimney. Heat is gen-
erated by both realistic flames. This heater
is designed for vent-free operation. It has
been tested and approved to ANSI Z21.11.2
standard for unvented heaters. State and lo-
cal codes in some areas prohibit the use of
vent-free heaters.
126861-01A
PRODUCT IDENTIFICATION
Access Door
Figure 1 - Vent Free Linear Fireplace
PRODUCT FEATURES
www.SuperiorFireplaces.US.com
SAFETY DEVICE
This fireplace has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free
room heaters. The ODS/pilot system shuts off
the fireplace if there is not enough fresh air.
Right
Side
Nailing
Flange
5