P900238-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
• See Table of Contents for location of additional Common-
wealth of Massachusetts requirements.
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
C
US
VRT3542WS Shown
Report No. F14-168
INSTALLATION AND
OPERATION INSTRUCTIONS
UNIVERSAL VENT-FREE FIREBOX
36" x 28" & 42" x 28"
Universal Vent-Free Fireboxes
P/N 900238-01 REV. D 10/2017
MODELS
VRT3536WS
VRT3536WH
FOR USE ONLY WITH A LISTED GAS-FIRED
UNVENTED DECORATIVE ROOM HEATER NOT TO
EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
WARNING: IMPROPER INSTALLATION, ADJUST-
MENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE INJURY OR PROPERTY DAMAGE.
REFER TO THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT A QUALI-
FIED INSTALLER, SERVICE AGENCY OR THE GAS
SUPPLIER.
Carefully review the instructions supplied with
the decorative type unvented room heater for the
minimum fireplace size requirement.
DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX
UNLESS THIS FIREBOX MEETS THE MINIMUM
DIMENSIONS REQUIRED FOR THE INSTALLATIONS.
THIS IS A VENT-FREE GAS-FIRED HEATER ENCLO-
SURE. IT USES AIR (OXYGEN) FROM THE ROOM
IN WHICH IT IS INSTALLED. PROVISIONS FOR
ADEQUATE COMBUSTION AND VENTILATION AIR
MUST BE PROVIDED. REFER TO COMBUSTION
AND VENTILATION AIR SECTION, PAGES 3 & 4.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appliance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM
HEATERS.
VRT3542WS
VRT3542WH

Advertisement

Table of Contents
loading

Summary of Contents for Superior Fireplaces VRT3536WS

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS UNIVERSAL VENT-FREE FIREBOX 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes P/N 900238-01 REV. D 10/2017 MODELS VRT3536WS VRT3542WS VRT3536WH VRT3542WH VRT3542WS Shown P900238-01 FOR USE ONLY WITH A LISTED GAS-FIRED INSTALLER: Leave this manual with the appliance.
  • Page 2: Important Safety Information

    IMPORTANT SAFETY WARNING WARNING INFORMATION Carbon Monoxide Poisoning: Early • The heater must be isolated from INSTALLER: PLEASE LEAVE THESE INSTRUC- signs of carbon monoxide poisoning the gas supply piping system by TIONS WITH THE OWNER. closing its individual manual are similar to the flu with head- OWNER: PLEASE RETAIN THESE INSTRUC- shut-off valve during any pres-...
  • Page 3: Table Of Contents

    CONGRATULATIONS! Misc. Codes / Standards - The Installation must conform to local codes In selecting this Superior Vent-Free Gas Firebox you have chosen the finest and most ® or, in the absence of local codes, with the dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a National Fuel Gas Code, ANSI Z223.1/NFPA wood burning fireplace.
  • Page 4: Combustion And Ventilation Air

    COMBUSTION AND VENTILATION AIR 2. Divide the volume of space by 50 ft Your options are: determine the maximum BTU/Hr the space can support. Heaters installed in these appliances shall a. Rework equations adding the space of adjoin- not be installed in a confined space. Heaters ing room(s).
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    NOTE: The following requirements reference LOCATION OF FIREBOX WARNING various Massachusetts and national codes Carefully select the best location for installation not contained in this document. Do not install these built-in Vent- of your built-in Vent-Free firebox. The following factors should be taken into consideration: Free fireboxes in sleeping quarters, or in recreational vehicles.
  • Page 6: Clearances

    Clearances Ceiling clearance: The ceiling must be at least 40" from the top of the firebox opening (Figure 2). Ensure the minimum clearances shown in Figures 2 through 6 are maintained. Left and right clearances are determined when facing the Noncombustible material: Noncombustible materials, such as slate and front of the firebox.
  • Page 7 Noncombustible material (minimum requirements) with wood mantel Combustible Mantel and Trim Clearance or other combustible projections: To install the firebox with a wood mantel, shelf or other combustible projection above firebox opening. Refer to Figures 4 and 5. Models VRT3536 & VRT3542 Series WITH Hood Installed Hood is optional on these models Minimum clearence requirements include any projections such as shelves, window sills, mantels, etc., above the appliance.
  • Page 8: Assembly Steps

    ASSEMBLY STEPS Consult all local codes. IMPORTANT NOTES: Properly size and route the gas supply line • Illustrations shown in this manual reflect Hold heater regulator with a wrench from the supply regulator to the area where the “typical” installations with nominal dimen- appliance is to be installed per requirements to prevent movement when connect- sions and are for design and framing refer-...
  • Page 9: Firebox Framing

    Firebox Framing NOTE: The nailing flange and the area directly 3. Note the floor construction, i.e. 2" x 6", 2" x behind the nailing flange is exempt from the 8" or 2" x 10", single or double joists, type clearances described on the firebox clearance Construct firebox framing following Figures 8 and thickness of floor boards.
  • Page 10: Specifications

    SPECIFICATIONS Dimensions - Inches (millimeters) Model No. VRT3536WS & 41-3/4 41-1/4 23-1/2 8-3/8 15-7/8 7-1/2 1-3/8 5-1/2 34-3/8 33-5/8 VRT3536WH (914) (711) (1061) (1048) (597) (508) (76) (213) (403) (190) (305) (35) (140) (873) (854) VRT3542WS & 47-3/4 41-1/4 29-1/2...
  • Page 11: Framing Specifications

    FRAMING SPECIFICATIONS Corner Installation Framing Dimensions Back Wall Of Chase/Enclosure This Figure corresponds to Table 1 Including Finishing Materials If Any Opening VRT3536 Series VRT3542 Series 42-1/4" (1073) 48-1/4" (1226) 44-1/4" (1124) 44-1/4" (1124) 23-5/8" (600) 29-5/8" (753) 11-1/4" (286) 14-1/4"...
  • Page 12: Optional Equipment / Blower Kit Installation

    IMPORTANT Top View * Junction Box * Electrical Outlet The Ground Lead must be connected to the green screw (located on the Hood junction box). Failure to do this Blower could result in an electrical short or Bend blower mounting shock injury.
  • Page 13 - see Step 8 on Page 14). Step 1. Follow the instructions below for the model you are installing: Models VRT3536WS, VRT3536WH, VRT3542WS & VRT3542WH: Screw Lift out the bottom refractory panel (see Figure 16). Step 2. Remove the rectangular knock-out (for J-Box) on the right side of unit (see Figure 7 for location).
  • Page 14 Step 10. Follow the instructions below for the model you are installing: Step 6. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply to the right side of appliance. Models VRT3536WS, VRT3536WH, VRT3542WS & VRT3542WH: Reinstall the bottom refractory panel that was removed on Step 1 (see Figure 16).
  • Page 15: Firebox Finishes

    FIREBOX FINISHES APPROVED ACCESSORIES AND COMPONENTS There are a wide variety of “finished looks” for your built-in Vent-Free firebox from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like marble, stone, tile, brick, etc. may overlap the black front facing.
  • Page 16 APPROVED ACCESSORIES AND The variable speed control COMPONENTS rheostat is included with FBK-200 models only * Forced Air Blower Kits Cat. Model No. Description Blower, Standard 80L84 FBK-100 (single speed) Black Hood Blower, Variable Speed 80L85 FBK-200 Cat. # Model Models Where Used (w/wall-mounted switch) VRT3536 Series...
  • Page 17: Replacement Parts List

    3. The part number. approved with this appliance may result in property 4. The description of the part. damage or personal injury. 5. The quantity required. 6. The installation date of the firebox. VRT3536WS VRT3536WH VRT3542WS VRT3542WH Description Whited Stacked...
  • Page 18 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...
  • Page 19: Warranty

    Innovative Hearth Products Superior Brand Gas Fireplaces, Stoves and Inserts ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials ®...
  • Page 20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and the discontinuance of colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A.