• immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions
• if you cannot reach your gas supplier,
call the fi re department
4. This fi replace shall not be installed in a
bedroom or bathroom.
5. Do not use this fi replace as a wood-burn-
ing fi replace. Use only the logs provided
with the fi replace.
6. Do not add extra logs or ornaments such
as pine cones, vermiculite, or glowing
embers. Using these added items can
cause sooting. Do not add volcanic stone
around base. Volcanic Stone and debris
could fall into the control area of fi replace.
7. This fi replace is designed to be smoke-
less. If logs ever appear to smoke, turn
off fi replace and call a qualifi ed service
person.
NOTE: During initial operation, slight
smoking could occur due to log curing and
fi replace burning manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
Page 23.
9. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
10. This fi replace needs fresh air ventilation to
run properly. This fi replace has an Oxygen
Depletion Sensing (ODS) safety shutoff

PRODUCT IDENTIFICATION

Log Set
Front
Burner
Remote
Control
Figure 1 - Log Base Assembly
4
SAFETY
Continued
system. The ODS shuts down the fi replace
if not enough fresh air is available.
See Air for Combustion and Ventilation,
Page 6. If fi replace keeps shutting off, see
Troubleshooting, Page 24.
11. Do not run fi replace
• where fl ammable liquids or vapors are
used or stored.
• under dusty conditions.
12. Do not use this fi replace to cook food or
burn paper or other objects.
13. Do not use fi replace if any part has been
under water. Immediately call a qualifi ed
service technician to inspect the room
fi replace and to replace any part of the
control system and any gas control which
has been under water.
14. Turn off and unplug fireplace and let
cool before servicing. Only a qualifi ed
service person should service and repair
fi replace.
15. Operating fi replace above elevations of
4,500 feet could cause pilot outage.
16. Do not operate fireplace if any log is
broken. Do not operate fi replace if a log
is chipped (dime-sized or larger).
17. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
lbs. capacity (propane/LP only).
18. Provide adequate clearances around air
openings.
19. The screen or any other part removed
for servicing must be replaced prior to
operating this heater.
Left Side
Top panel
Assembly
Fireplace
Hood
Magnet
Base
Assembly
Screen
Assembly
SuperiorFireplaces.us.com
Top Outer Casing
Bottom Panel
Assembly
Figure 2 - Fireplace
900719-00B