Icom IC-F5060 Series Operating Manual page 40

Biis 1200/mdc 1200 system/ ltr/idas operation
Hide thumbs Also See for IC-F5060 Series:
Table of Contents

Advertisement

5
IDAS OPERATION
D Transmitting a Remote Monitor Call
A remote monitor call will send a signal that requires the tar-
geted station to transmit its microphone audio.
q Push [Digital Button] to enter the application selection
mode.
• "VOICE" appears.
• To change the call type, hold down [Digital Button] for 1 second in
the standby mode. After changing, the transceiver automatically
enters the application selection mode.
w Push [CH Up] or [CH Down] to select "REM MON."
e Push [Digital Button] again to enter the Individual ID se-
lection mode.
• A preprogrammed ID name is displayed.
• When an ID name is not programmed, an ID code is displayed.
• The primarily ID can be preset to display first.
This function is usable in transceivers whose revision number is
2.9 or later. Ask your dealer for details.
r Push [CH Up] or [CH Down] to select the desired ID name
or ID code.
• Depending on the presetting, you may be able to directly input
the ID. (The optional HM-152T is required.) See page 43 for de-
tails.
R E M
S T A T I O N
The individual ID name is displayed.
37
M O N
1
t Hold down [PTT] to transmit the Remote monitor call to
the selected station.
• "REM TX" is displayed.
y Release [PTT].
• "REM ACK" is displayed if an acknowledgement is received from
the targeted station.
• "REM FAIL" is displayed if no acknowledgement is received from
the targeted station.
u After a specified time period has passed, your transceiver
will return to the standby mode.