E. Glass Assembly
WARNING
Handle glass doors with care.
• Inspect the gasket to ensure it is
undamaged.
• Inspect the glass for cracks, chips or
scratches.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door removed,
cracked, broken or scratched.
• Replace glass door assembly as a complete appliance.
Removing Glass Assembly
Pull the two glass assembly latches out of the groove on
the glass frame. Remove glass door from the appliance
(see Figure 12.10).
Replacing Glass Assembly
Replace the glass door on the appliance. Pull out and
latch the two glass assembly latches into the groove on
the glass frame.
Figure 12.10 Glass Assembly
GLASS
ASSEMBLY
BOTTOM
LATCH
Heat & Glo • Soho24B • 2137-900 Rev. o • 8/11
F. Air Shutter Setting
Burner
G. Refl ective Panel
The back and sides of the SOHO are covered with a
refl ective panel. This panel will bronze with burning, but
it will retain its refl ectivity.
NG
LP
1/16 in.
Full Open
37