TROUBLESHOOTING CUBE ICE
MAKERS
STATUS INDICATORS 300 AND 322 SERIES
1.
No Lights
Unit in freeze cycle.
2.
Flashing Red Bridge thickness temperature
has been reached. Harvest to
start in approximately 30 seconds
3.
yellow
Unit in Harvest Cycle
4.
Green
Unit off on Full Bin
STATUS INDICATORS 500 THRU 1400
SERIES
STATUS
EXPLANATION
0
Unit is in freeze cycle, making ice, no prob-
lems.
1
Unit is in harvest cycle, ice should drop
shortly, no problems.
2
Indicates a full bin condition, unit off, water
curtain being held open with ice.
4
Unit OFF due to suction line not pulling
down to at least 40°F.
6
Unit is OFF due to condenser temperature
climbing too high. Manual reset required.
Decimal
Indicates that all sensors, except condens-
Point OFF
er, are switched off for first six minutes of
freeze cycle.
Decimal
Indicates that evaporator and suction line
Point ON
sensors have switched "ON".
Decimal
Indicates evaporator temperature has
Point
pulled down and unit will go into harvest
FLASHING
after time delay.
FOR MANUAL RESET - PUSH MASTER SWITCH TO
"OFF" - WAIT 10 SECONDS - PUSH TO "ON" OR PUSH
RESET BUTTON

TROUBLESHOOTING THE SENSORS

1.
Turn off power to machine.
2.
Remove the front panel and electrical box cover of
the machine.
36