Request to Exit (RTE)

A Request to Exit switch may be fitted on the secure side of the door. This should be a
normally-open switch that closes momentarily when pressed and released. Do not allow the
wiring for the RTE switch to be visible if the reader is removed from the wall.

Reader Wiring

If you do not intend to use the RTE switch then unscreened 4-core cable will be suitable;
otherwise use 6-core cable.
-V1 S1 R1 A1 +V1
A Terminal Block
Use 7/0.2mm (0.22mm²) 4-core or 6-core unscreened cable.
Controller:
Channel 1
+V1
S1
R1
A1
-V1
Note: The reader outputs are set at 90mA. Stanley Security Products strongly recommend
that you fit a 100mA in-line fuse in the reader supply.
A
100 mA
B
Reader Wiring, including RTE
B RTE
Colour:
Channel 2
+V2
Red
S2
Blue
R2
White
A2
Yellow
-V2
Black
19
+V
SIG
VCA
-V
C
C
Reader
Reader:
+V
SIG
n/c
VCA
-V

Hide quick links: