Interrupting a programme

A programme can only be
interrupted in operating level B or D.
If you absolutely have to open the door,
e.g. because the load is obviously
unstable (conscious intervention):
After interrupting a DESIN
disinfection programme, if you wish
to continue it please check the
message in the display at the end of
the programme. If the message
PROCESS PARAMETERS NOT MET
is displayed, it means the door was
opened after the disinfection part of
the programme and the DESIN
parameters were not fulfilled. If
necessary the programme must be
repeated.
In operating levels B or D
^ Press the Stop button 7. The
programme is interrupted.
If the water temperature is below
40 °C CANCEL OR üCONTINUE<
will appear in the display, and if it is
above 40 °C üCANCEL< will appear
in the display.
^ Open the door.
,
Warning. Water and items in the
machine may be hot. Danger of
burning or scalding.
Where a chemical disinfection
programme has been used, be
aware that steam may contain high
quantites of disinfecting agent.
^ Rearrange the load. Follow infection
control regulations and wear
protective gloves.
^ Close the door slowly.
,
If a great deal of hot water is
present in the wash cabinet when
the programme is interrupted and
the door is then closed quickly, hot
water can escape.
Danger of burning or scalding.
If the water temperature is lower than
40 °C when the programme is
interrupted:
^ Press the Start button 6 to continue
the programme.
If the water temperature is higher than
40 °C when the programme is
interrupted:
^ Press the Start button 6.
The programme is cancelled and the
water pumped away. DRAIN WATER
appears in the display.
^ Once the water has been pumped
away, the programme can be
restarted.