2.2.3
Test print mode (Test mode 07)
The embedded test pattern can be printed out by keying in the following codes in the test print mode
(07).
<Operation procedure>
[0][7]
[POWER]
[Digital keys]
Notes:
1. Test printing is set by default to continue until the [CLEAR] button is pressed, or an error
occurs. Note that printing may therefore continue until the paper set in the specified drawer
completely runs out.
2. When an error occurs, it is indicated on the panel, but the recovery operation is not per-
formed. Turn OFF the power and then back ON to clear the error.
3. During test printing, all button operations are disabled when the Message lamps on the con-
trol panel light.
Code
111
Primary scanning direction 33 gradation steps
113
Secondary scanning direction 33 gradation steps
142
Grid pattern
149
Solid black pattern (Whole area)
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
Code
[START]
Types of test pattern
Drawer number
[Digital keys]
0: Bypass
1: Drawer
2: PFU
Operation
Continuous
Test Printing
[START]
Error diffusion
Error diffusion
Pattern width: 2 dots, Pitch: 10 mm
A3/LD
2 - 10
06/04
[START]
Stop
[POWER]
[CLEAR]
OFF/ON
Remarks
December 2005 © TOSHIBA TEC