3.7.3
Scan motor (CIS unit drive belt-2)
When installing the scan motor and CIS unit drive belt-2, adjust the tension of the CIS unit drive belt-2
with the belt tension jig.
<Procedure>
(1)
Temporarily fix screws A and B.
(2)
Hook the belt tension jig on the motor
bracket and frame.
(3)
Tighten screws A and B where the scan motor pulled by the belt tension jig stops.
e-STUDIO163/203 ADJUSTMENT
Scan motor
3 - 40
A
B
Scan motor
Fig. 3-26
Belt tension jig
Fig. 3-27
December 2005 © TOSHIBA TEC