Orifice Holders; Removing Manifold Panel - Electrolux EW30DF65GB Service Manual

Electrolux ew30df65g and cewdf65g series freestanding dual fuel range
Hide thumbs Also See for EW30DF65GB:
Table of Contents

Advertisement

orifice holders

Once the cooktop has been removed the
Photo A
individual orifice holder assemblies are
accessible for service. (Photo A)
Orifice Holder
Assemblies
Each orifice holder assembly is connected to
the burner valve by a compression fitting on
the end of the gas supply line. (Photo B)
The supply line is part of the orifice holder
assembly. Use care when removing and
installing the compression fitting onto the
burner valve.
Photo B
When disconnecting the ignitor wire from
Photo C
the ceramic ignitor on the orifice holder you
must depress the locking tab in order for the
terminal connector to release.
Depress Tab
To Release

Removing Manifold Panel

Remove the four mounting screws indicated in
Photo D
photo D on the underside of the manifold panel.
Remove the burner valve control knobs by pulling
them straight forward off the valve shafts.
Next remove the ¼" hex head screws securing
Remove Three
each of the main top mounting clips. Remove the
Photo E
Screws
1/4" hex head screw in the center of the manifold
panel and remove the panel from the range.
(Photo E)
With the manifold panel removed the surface
burner ignitor switches and harness are
accessible. The wire harness and switches are
replaced as a complete assembly.
Page 29