Notes for the installer

This machine must be installed by an
authorised technician only. In the U.K. gas
heated machines must be installed by a
Corgi registered fitter only.
,
This machine is not designed for
washing items which have been treated
with dangerous or flammable substances.
The machine must be level and secure after
installation (see installation diagram
supplied with the machine).
To avoid the risk of frost damage do not
install this machine in a room where there is
a risk of frost occuring.
Do not install the machine on carpeted
flooring as the carpet pile can hinder the
free flow of air into the ventilation gaps at the
bottom of the machine.

Transit fittings

The red marked transit fittings, 2 at the front
and 2 at the back are each secured in
position with 3 hex screws. These have to be
removed on-site before the machine can be
commissioned.
40
To do so the front panel and the rear panel
of the machine have to be removed.
Unscrew the screws from the bottom edge of
the front panel and then take the front panel
off.
Unscrew the screws from the back panel
and then take the back panel off.
Store the transit fittings in a safe place for
future use. They will need to be refitted
should the machine every need to be
moved to another location.
The machine must not be moved without
all the outer panels in place.