Power Consumption Monitoring Function - Fujitsu Sun Oracle SPARC Enterprise M3000 Overview Manual

Hide thumbs Also See for Sun Oracle SPARC Enterprise M3000:
Table of Contents

Advertisement

For details of the showenvironment(8) command, refer to the man page. For
installation details of the SPARC Enterprise M3000 server, see the SPARC Enterprise
M3000 Server Site Planning Guide and the SPARC Enterprise M3000 Server Installation
Guide.
You can also obtain the exhaust air data using the SNMP agent function. To obtain
the data of exhaust air using the SNMP agent function, install the latest XSCF
extension MIB definition file to the SNMP manager. For details on the XSCF
extension MIB definition file, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide.
2.6.4

Power Consumption Monitoring Function

The power consumption monitoring function confirms the amount of power
consumed while the SPARC Enterprise M3000 server is up and running.
To display the power consumption, use the showenvironment power command.
CODE EXAMPLE 2-2
XSCF> showenvironment power
Permitted AC power consumption:470W
Actual AC power consumption:450W
Note – The values displayed by the power consumption monitoring function are for
reference only. The power consumption value of the server varies by the conditions
such as the power supply in use, CPU types, or system configurations, or system
load.
For details of the showenvironment(8) command, see the man page. For
installation details of the SPARC Enterprise M3000 server, see the SPARC Enterprise
M3000 Server Site Planning Guide.
You can also obtain the power consumption data using the SNMP agent function. To
obtain the power consumption data using the SNMP agent function, install the latest
XSCF extension MIB definition file to the SNMP manager. For details on the XSCF
extension MIB definition file, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User's Guide.
When there is a change in the power system, such as in the following occurrences,
wait for one minute, then check the value again.
During the server power-on or power-off, or after the power-on or power-off is
complete
2-10
SPARC Enterprise M3000 Server Overview Guide • March 2012