NOTE: Temperature compensated hand-type refractometers (P/N 511004000) are available from the Cornelius
Company.
7. Observe pressure setting on carbonator secondary CO
8. Press applicable ''AUTO BLEND 1'' or ''AUTO BLEND 2'' switch to fill product blender tank 1/4-full of new
batch of product. When product blender tank is 1/4-full of product, press applicable ''FILL 1'' or ''FILL 2''
switch to prevent more product from entering product blender tank.
9. Repeat steps 6 and 7 preceding to check product sample for BRIX.
10. Repeat steps 7 through 10 preceding until proper BRIX adjustment is achieved.
11. Open product shutoff valve in line between product blender tank and freeze cylinder.
12. Press applicable ''AUTO BLEND 1'' or ''AUTO BLEND 2'' switch.
13. Install Unit side panels and lower front access panel by reversing removal procedures.

PRODUCT CARBONATION ADJUSTMENT

(see Figures 2 and 8)
Carbonation of dispensed product can also be varied to suit consumer preference by adjusting Unit carbonator
secondary CO
regulator as follows:
2
IMPORTANT: Carbonator tank secondary CO
product blender tanks secondary CO
pressures must be able to overcome and vent product blender tanks head pressures while tanks are
filling with carbonated water and syrup. Carbonator tank secondary CO
enough will cause decreased flow of carbonated water into blender tanks, which will increase BRIX of
dispensed product.
1. Remove Unit lower front access panel as instructed for access to carbonator secondary CO
with 100-psi gage.
2. Observe pressure setting on carbonator secondary CO
3. To lower CO
pressure, loosen regulator adjusting screw lock nut. Turn adjusting screw to the left (counter-
2
clockwise) until pressure gage reads 15-psi below desired reading, then turn screw to the right (clockwise)
until gage reads desired pressure. DO NOT SET CO
ER THAN PRODUCT BLENDER TANKS CO
IMPORTANT NOTE). Tighten adjusting screw lock nut after each adjustment.
4. Observe pressure setting on carbonator secondary CO
5. To raise CO
pressure, turn regulator adjusting screw to the right (clockwise) until gage reads desired pres-
2
sure. DO NOT SET PRESSURE HIGHER THAN 60-PSI. Make sure primary CO
der is set at 80 to 100-psi. Tighten adjusting screw lock nut after each adjustment.
6. Install lower front access panel on Unit.

CLEANING AND SANITIZING

DAILY CLEANING OF UNIT

Daily, or more often if necessary, wash all external surfaces of Unit with a mild soap solution. Rinse with clean
water, then wipe dry with a clean soft cloth. DO NOT USE ABRASIVE CLEANERS. Remove and wash drip tray
in mild soap solution, rinse with clean water, then install drip tray on Unit.
2992
regulator gage.
2
regulator must be adjusted 25-psi higher or more above
2
regulators pressure settings. Carbonated water and syrup
2
regulator gage.
2
REGULATOR PRESSURE BELOW 25-PSI HIGH-
2
REGULATORS ARE ADJUSTED TO (SEE PRECEDING
2
regulator gage.
2
48
regulator not adjusted high
2
regulator
2
regulator on CO
2
cylin-
2