This section describes operating controls and indicators, dispensed product conditions, operating characteris-
tics, Unit operation, replenishing syrup supply, product flavor change, checking CO
cleaning of Unit, and sanitizing requirements.
WARNING: Disconnect electrical power to the Unit to prevent personnel injury before
attempting any internal maintenance. Only qualified personnel should service internal
components or electrical wiring.
NOTE: The No. 1 freeze cylinder (see Figure 7) is the left-hand cylinder facing the front of the Unit. No.
2 freeze cylinder is to the right of the No. 1 freeze cylinder.

CONTROL PANEL ASS'Y SWITCHES AND DISPLAYED MESSAGES

CONTROL PANEL ASS'Y SWITCHES

(see Figure 5)
NOTE: The Unit control panel assembly is equipped with a hidden "SECURITY SWITCH" located be-
tween "FILL 1" and "ERROR RESET" control switches (see Figure 5). Pressing in and holding "SE-
CURITY SWITCH" for 3 seconds deactivates the control switches preventing tampering with Unit nor-
mal operation. To reactivate the control switches, press in and hold the "SECURITY SWITCH" for 3
seconds.
''FILL 1'' and ''FILL 2'' Control Switches.
''FILL 1'' and ''FILL 2'' control switches, located on control panel assembly, are touch-type switches and require
only pressing to activate. ''FILL 1'' and ''FILL 2'' control switches are used when filling syrup systems sold-out
floats during syrup replenishing, syrup flavor changeover, or sanitizing syrup systems. After syrup systems sold-
out floats have been filled, ''FILL 1'' and ''FILL 2'' switches may be used to prevent more product entering prod-
uct blender tanks during the BRIX test.
''AUTO BLEND 1'' and ''AUTO BLEND 2'' Control Switches.
''AUTO BLEND 1'' and ''AUTO BLEND 2'' control switches, located on control panel assembly, are touch-type
switches and require only pressing to activate. These switches are used to fill product blender tanks after sol-
out floats have been filled using ''FILL 1'' and ''FILL 2'' switches. ''AUTO BLEND 1'' and ''AUTO BLEND 2'' and
''AUTO 1'' and ''AUTO 2'' switches must be pressed to operate freeze cylinders beaters and refrigeration sys-
tem during normal operation.
''WASH 1'' and ''WASH 2'' Control Switches.
''WASH 1'' and ''WASH 2'' control switches, located on control panel assembly, are touch-type switches and re-
quire only pressing to activate. These switches are used to operate freeze cylinders beaters with no refrigera-
tion during sanitizing.
"AUTO 1" and ''AUTO 2" Control Switches.
''AUTO 1'' and ''AUTO 2'' control switches, located on control panel assembly, are touch-type switches and re-
quire only pressing to activate. These switches are used to operate freeze cylinders beaters and refrigeration
system after cylinders have been filled with product. Freeze cylinders beaters and refrigeration system may be
stopped by pressing ''OFF 1'' or ''OFF 2'' switches.