Normal Operation - Stage 5; Normal Operation - Stage 6 - Follett Symphony 25CI400A Installation, Operation And Service Manual

Ice and water dispensers
Hide thumbs Also See for Symphony 25CI400A:
Table of Contents

Advertisement

Normal operation – Stage 5
The drive motor now shuts down and the DR LED is off. The B-T LED remains on for 20 minutes. The icemaker will not
start while the B-T LED is on. To restart the icemaker for troubleshooting purposes, depress the reset button to clear
the control board.
INPUT
POWER
G
B
W
COMPRESSOR
T.O.L.
RED
WHITE
Normal operation – Stage 6
When the dwell time of 20 minutes has expired, the B-T LED goes off. The icemaker goes through the normal start-
up sequence when the bin level control signals the control board for ice. The WTR LED will remain on as long as the
water sensor in the fl oat reservoir senses water.
INPUT
POWER
G
B
W
COMPRESSOR
T.O.L.
RED
WHITE
26
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
ORANGE
C
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
START
GEAR MOTOR
RELAY
START
4
2
BLACK
3
YELLOW
RUN
START CAP.
GEAR MOTOR
START
RED
RUN
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
ORANGE
C
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
START
GEAR MOTOR
RELAY
START
4
2
BLACK
3
YELLOW
RUN
START CAP.
GEAR MOTOR
START
RED
RUN
WATER
SENSOR
WHITE
WHITE
RED
BLACK
1
L
BLACK
BLACK
BISON GEARMOTOR
T.O.L.
OR
LINIX GEARMOTOR
T.O.L.
WATER
SENSOR
WHITE
WHITE
RED
BLACK
1
L
BLACK
BLACK
BISON GEARMOTOR
T.O.L.
OR
LINIX GEARMOTOR
T.O.L.
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
PWR
RESET
GRD
DR
L1
L1
C
L2
20M
CONTROL
L2
BOARD
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
PWR
RESET
GRD
DR
L1
L1
C
L2
20M
CONTROL
L2
BOARD
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
RED
RED
RED
RED

Advertisement

Table of Contents
loading

Table of Contents