Normal Operation - Stage 3; Normal Operation - Stage 4 - Follett Symphony 25CI400A Installation, Operation And Service Manual

Ice and water dispensers
Hide thumbs Also See for Symphony 25CI400A:
Table of Contents

Advertisement

Normal operation – Stage 3
After the initial high current draw drops off, the gearmotor start relay contacts open, dropping out the start winding (or
start capacitor). As the compressor comes up to normal running speed, the compressor start relay contacts also open,
dropping out the start winding of the compressor. The icemaker is now in a normal icemaking mode. The icemaker will
begin to produce ice and continue to produce ice until the bin level control in the ice dispenser is satisfi ed. The PWR,
B-E, DR, C and WTR LEDs are all on.
INPUT
POWER
G
B
W
COMPRESSOR
T.O.L.
RED
WHITE
Normal operation – Stage 4
Once the ice level control opens, the B-E LED goes out. After a 10 second delay the compressor LED (C), compressor
and fan motor go off. (Should the ice level control not remain open for 10 seconds, the icemaker will continue to run.)
The gearmotor continues to run and the DR LED remains lighted for 60 seconds. The purpose of this function is to
drive the remaining ice out of the evaporator and to boil off any refrigerant remaining in the evaporator. The bin timer
LED (BT) comes on, starting the twenty minute off cycle time delay.
INPUT
POWER
G
B
W
COMPRESSOR
T.O.L.
RED
WHITE
25CI400A/W • 25HI400A • 50CI400A/W • 50HI400A
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
ORANGE
C
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
START
GEAR MOTOR
RELAY
START
4
2
BLACK
3
YELLOW
RUN
START CAP.
GEAR MOTOR
START
RED
RUN
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
ORANGE
C
S
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
START
GEAR MOTOR
RELAY
START
4
2
BLACK
3
YELLOW
RUN
START CAP.
GEAR MOTOR
RED
START
RUN
WATER
SENSOR
WHITE
WHITE
RED
BLACK
1
L
BLACK
BLACK
BISON GEARMOTOR
T.O.L.
OR
LINIX GEARMOTOR
T.O.L.
WATER
SENSOR
WHITE
WHITE
RED
BLACK
1
L
BLACK
BLACK
BISON GEARMOTOR
T.O.L.
OR
LINIX GEARMOTOR
T.O.L.
PWR
RESET
GRD
DR
L1
L1
C
L2
20M
CONTROL
L2
BOARD
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
PWR
RESET
GRD
DR
L1
L1
C
L2
20M
CONTROL
L2
BOARD
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
RED
RED
RED
RED
25

Advertisement

Table of Contents
loading

Table of Contents