44
SYMPTOM
Blower does not turn on
Door sticking
W415-0098 / H / 03.19.12
PROBLEM
Blower high limit switch has
been activated
Dirt / dust adheres to the
hinges; is heated and burns
causing sticking.
TEST SOLUTION
-
Turn blower switch on, turn turbo rear burner off and
front burner to low. When blower turns on, re-adjust
burners.
-
Lift door from its hinges. Lubricate with high-temp dry
graphite only.
-
NOTE: Due to high temperatures that the hinges
experience, wet lubricants such as oil and WD40
will cause the hinge to seize and are therefore not
suitable.