Installation; Minimum Clearance To Combustibles - Napoleon GDS50N Operating Instructions Manual

Natural & propane gas vented gas fireplace heaters
Table of Contents

Advertisement

18

4.0 INSTALLATION

FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS
ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED
RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC
W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR
IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS, 3 SCREWS MUST ALSO BE USED TO
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. IMPROPER SUPPORT OF THE ENTIRE VENTING
SYSTEM MAY ALLOW VENT TO SAG AND SEPARATE. USE VENT RUN SUPPORTS AND CONNECT
RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.
REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TO
4.1

MINIMUM CLEARANCE TO COMBUSTIBLES

As long as clearance to combustibles is kept within required distances, the most desirable and benefi cial location for an
appliance is in the centre of a building, thereby allowing the most effi cient use of the heat created. The location of windows,
doors and the traffi c fl ow in the room where the appliance is to be located should be considered. If possible, you should
choose a location where the vent will pass through the house without cutting a fl oor or roof joist.
MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
A. 7"
B. 2"
B
BACK WALL
E
Minimum 20" from appliance top to ceiling
* At a distance of 1" from the wall, access to the blower switch, on-off switch or the blower power cord may not
be practical.
W415-0098 / H / 03.19.12
WHICH MUST BE SEALED USING MILL PAC.
ENSURE THE CONNECTION CANNOT SLIP OFF.
DO NOT CLAMP THE FLEXIBLE VENT PIPE.
VENT SECTIONS PER INSTALLATION INSTRUCTIONS.
MAINTAIN CLEARANCES TO COMBUSTIBLES.
C. 1"*
D. 17 1/2"
A
A
D
WARNING
!
EXACTLY.
E. 6 1/4"
F. 9 1/2"
B
A
ALCOVE
68.2A
BACK WALL
45°
F
C

Hide quick links: