Graco M73109 A Series Instructions-Parts List Manual page 14

Turbine spray guns series 700, 800, and 900
Table of Contents

Advertisement

WARNING
Turn off turbine and unplug power for the following
procedures.
Turbine Switch Replacement (Red Rocker Circuit
Breaker)
1. To remove the turbine switch (3), wedge a large
flat blade screwdriver between the top of the
switch and the turbine face plate. See Fig. 6.
2. Push down firmly on the switch. Pry the switch out
far enough so the two top switch locking tabs are
visible.
3. While maintaining outward pressure on the switch,
push down on the two locking tabs with a small flat
blade screwdriver until they release. The switch
will pop out.
4. Disconnect the two wires and remove the switch.
5. Reinstall by connecting wires to the new switch.
Snap the switch into place.
Locking Tabs
3
Fig. 6
Series 800 Compressor Replacement
1. Remove the four main filter stop screws and
remove the main filter. (Clean or replace filter as
necessary).
2. Remove the air hose from the "out" side of the
compressor.
3. Locate and remove the three compressor hold–
down screws.
4. Remove the ground screw. Clip the lead wires and
remove the compressor.
5. Rewire and install the new compressor. Apply
removable Loctite on the compressor screws and
tighten the screws. Do not overtighten the rubber
bumpers.
Repair
6. Reinstall the hose on the "out" side of the com-
pressor.
7. Replace the main filter.
Wrapper Removal
Remove the cabinet wrapper by following these steps.
1. Remove the four filter screws. Remove the main
filter. Clean and replace the filter if necessary.
2. Remove the four remaining top wrapper screws.
Do not remove handle screws.
3. Remove one screw from each side of the wrap-
per.
4. Remove the four remaining bottom wrapper
screws. Do not remove the rubber feet.
5. Gently pry loose and remove the wrapper from the
cabinet.
NOTE: The wrapper is sealed with caulk.
03728
Fig. 7
Power Cord Replacement
Remove the cabinet wrapper by following the Wrapper
Removal procedure.
The power cord may now be replaced.
Series 800 Compressor Toggle Switch Replace-
ment
Remove the cabinet wrapper by following the Wrapper
Removal procedure.
The compressor toggle switch (Series 800) may now
be replaced.
Wrapper
Screws
Side
Screws
Series 900 shown
Filter
Screws
03067