Jma-5206/Hs Type Radar - JRC JMA-5206 Instruction Manual

Table of Contents

Advertisement

11.1
(1) Type of Emission
(2) Display
(3) Screen
(4) Range Scale
(5)
Range Resolution
(6) Minimum Detective Range
(7) Range Accuracy
(8) Bearing Accuracy
(9) Bearing Indication
(10) Ambient Condition
(11) Power Supply Input
(12) Power Consumption
(13) Power Supply Voltage
Fluctuation
(14) Pre-heating Time

JMA-5206/HS TYPE RADAR

P0N
Color Raster Scan
15-inch Color LCD
Effective diameter of radar display, more than 180 mm
0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48, 96nm
Less than 25m
Less than 28m
Less than 1% of the maximum distance of the range scale in use or
less than 15m whichever is larger
Less than 1°
Relative Motion mode: Head-up/Course-up/North-up
True Motion mode:
According to IEC60945-4
Temperature
Scanner:
(Storage Temperature:
Other Unit except Scanner: -15 to +55℃
Relative Humidity
93% at +40℃
Vibration
2 to 13.2Hz, amplitude ±1mm ±10%
13.2 to 100Hz, acceleration 7m/s
Velocity of the wind
51.5m/s(100kt)
+24VDC (Display Unit)
+24VDC (Scanner)
* Display Unit and Scanner correspond to 100VAC/220VAC
when use NBA-3308.
Approx. 300W (In maximum wind velocity)
+32V/24V/12VDC –10/+30% (JMA-5206)
+24VDC –10/+30% (JMA-5206HS)
Approx. Within 1min30sec
11─1
Course-up/North-up
-25 to +55℃
-25 to +70℃)
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jma-5206hsJma-5220-9Jma-5210-4Jma-5210-6Jma-5220-7

Table of Contents