EXISTING FAN
E
Remove an existing fan and check to make sure the
Move the housing into position above the ceiling.
opening is large enough to accommodate the new motor
housing (7 1/4"x 7 3/4").
B13
B14
Route wires through the strain relief. For supply connec-
Attach existing ducting to duct connector. Tape joints.
tion, use wires suitable for at least 90º C (194º F).
If ducting does not fit securely,
an adapter may need to be purchased.
B15
E
Install the housing flush with the sheetrock and secure by
tightening the pre-loaded screws into the joist.