(located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.
Check all the parts. If damaged, call 1-888-830-1326 for replacements. 3/8" Cable Connector 3/8" Cable Connector Extra Screws Extra Screws NOTE: Strain relief cable connector NOTE: Strain relief cable connector must be installed. Not Included. must be installed. Not Included. Before Installation Turn off the power source.
New Construction Installation Loosen screw securing motor. Remove the motor/blower from the housing. Remove packing material. Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the Remove the wiring cover screw. side of the housing. 41788-01 6/1/2005...
Page 6
Remove the wiring cover. Insert the strain relief into the housing and secure with the washer. Screw pre-loaded screws into joist or framing. 41788-01 6/1/2005 Pop out the first wiring access slug. Use second if needed. Position the correct depth mark at the bottom edge of the joist–based on the thickness of your sheet rock.
Page 7
Pull the wires through the strain relief. 2 Pin Fan Motor 3 Pin Light *Option Fan & Main Light Together Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Ground Black...
Page 8
0 0 0 0 0 0 0 0 Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws.
Page 9
Use the motor housing as a template to mark position. Cut out an opening for the housing. Existing Fan Remove the existing fan and check to make sure the Loosen screw securing motor. opening is large enough to accommodate the new motor housing (7.25”...
Page 10
Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover screw. Remove the wiring cover. Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer.
Page 11
Move the housing into position above the ceiling. Pull the wires through the strain relief and tighten the strain relief screws. Attach existing ducting to duct connector. Tape joints. Fit housing into the opening and secure by tightening the If ducting does not fit securely, pre-loaded screws into the joist.
Page 12
2 Pin Fan Motor 3 Pin Light *Option Fan & Main Light Together Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 0 0 0 0 Reinstall the motor by inserting the tabs and pushing up into position.
Page 13
O F F Test the motor. If the motor does not run, Turn on the power source. check the plug connection. Go to step to attach grille. Attaching the Grille Remove the thumbscrews. Remove glass dome. 41788-01 6/1/2005...
Page 14
Connect wiring harness. Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. Align glass dome and push up. 41788-01 6/1/2005 Install 2 Max 60 Watt A15 bulbs (Not Included). Slide light mount over posts. Screw glass dome into position.
Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker.
If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or workmanship, labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service Department in Memphis, Tennessee.