  • Page 1 Ashbury Bath Ventilator with Light Owner’s Manual Model 87001 48029-01 20100614 42901-01 06/14/2010 ©2010 Hunter Fan Co.
  • Page 2: Preventative Maintenance

    TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Engineers (ASHRAE), and the local code authorities. 1. Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer. 5.
  • Page 3: Before Installation

    Check all the parts. 95047-03-000 If damaged, call 1-888-830-1326 75864-02-000 for replacements. 03242-07-133 95261-02-000 74508-03-133 77522-01 3/8” Cable Connector 65219 96397-01-214 for model 87001 96397-02-444 for model 87003 75184-01-133 Extra Screws 86812-01-000 for model 87001 NOTE: Strain relief cable 86812-03-000 for model 87003 connector must be installed.
  • Page 4 Remove the motor/blower from the housing. Remove packing material. Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover screw. Remove the wiring cover. 42901-01 06/14/2010...
  • Page 5: New Construction

    Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Choose Installation Option For New Construction - go to step A11, page 5 For Existing Construction - go to step B11, page 8 New Construction Position the correct depth mark at the bottom edge of the Screw pre-loaded screws into joist or framing.
  • Page 6 Route wires through the strain relief. For supply connection, use wires suitable for at least 90º C (194º F). Ground Black Green 2 Pin Bare Copper White Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Black Light Light *Option...
  • Page 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Connect wiring harness. DO NOT ALLOW THE MOTOR TO Reinstall the motor by inserting the tabs and pushing up HANG FROM THE WIRING HARNESS. into position.
  • Page 8: Existing Construction

    Existing Construction EXISTING FAN Remove an existing fan and check to make sure the Move the housing into position above the ceiling. opening is large enough to accommodate the new motor housing (7 1/4”x 7 3/4”). Route wires through the strain relief. For supply connec- Attach existing ducting to duct connector.
  • Page 9 Ground Black Green 2 Pin Bare Copper White Black Main Switch 1 (AC In) Fan Motor White White 3 Pin Light Black Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. Install the wiring cover plate. Connect wiring harness.
  • Page 10 O F F Test the motor. If the motor does not run, Turn on the power source. check the plug connection. Go to step on page 10 to attach grille. Attaching the Grille Remove the thumbscrews. Remove glass dome. 42901-01 06/14/2010...
  • Page 11 Connect wiring harness. DO NOT ALLOW THE FIXTURE Remove the strain relief bracket screw. TO HANG FROM THE WIRING HARNESS. Insert the strain relief bracket’s dog-leg tab so that Position the strain relief bracket under the it hooks over the lip of the motor. Reinstall the motor as shown.
  • Page 12 Align glass dome and push up. Install 2 Max 60 Watt A15 bulbs (Not Included). Screw glass dome into position. 42901-01 06/14/2010...
  • Page 13: Troubleshooting

    Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker.
  • Page 14: Warranty

    If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or work- manship, labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service Department in Memphis, Tennessee.