Event Monitoring; Spot-Out Monitoring - Samsung SHR-2160 User Manual

Real time
Hide thumbs Also See for SHR-2160:
Table of Contents

Advertisement

SHR-2160/2162/2080/2082 USER'S MANUAL
5

Event Monitoring

Event monitoring displays the channel synchronized with a event on the screen when a special
event (Sensor/Motion/Video Loss) occurs. Event monitoring On/Off and event duration setup is
available in [Menu] [Monitoring] mode.
If you set the event monitoring interval to 5 seconds and an event occurs at CH2 in
the beginning as following figure, the system will display CH2 in the full screen for 5 second.
If another event occurs within 5 seconds, it is displayed together with the existing event. As the
following figure, both CH1 and CH3 events occur within 5 seconds (for example, after 4
seconds) after occurring CH2 event, these three events are split into 4 screens.
If the new event does not occurs during the event duration, the system will return to the
previous Live mode. Pressing the [ALARM] button during the event duration makes the event
monitoring stop. On occurring an event, [ALARM LED] is turned on. Press the [ALARM] button
to turn [ALARM LED] off.
The alarm setup is initialized and the event icon disappears, and the event monitoring is off if it
is on when pressing the [ALARM] button. After alarming, the event recording is continued again
for set time.
4-7
6

Spot-out monitoring

Spot-out Monitoring has nothing to do with Live Screen Output, it monitors the full screen of a
certain channel. If you select the Monitoring in the MENU, the one channel among CH1 ~ CH4
is output with a Spot-out or channels are output one by one at an interval as Auto Sequence
Mode in the Live Mode. Live screen icon does not appear in the spot-out monitoring.
The interval is as same as the Auto Sequence time in the Live Mode. If the Spot-out Event
Monitoring is On, it is possible to see the event channel with Spot-out. In case of simultaneous
event occurrence at more than one channel, the lowest numbered event channel has the first
priority to be spotted out.
Caution
Caution
If the built-in HDD is not connected, or it operates with power applying in error,(
indicating "built-in HDD error" is displayed at the top of left.
At this time,
(1) Live screen mode
(2) Monitoring mode by Smart Viewer
operate only and the other functions including recording, search, playback, menu
setup, and PTZ do not operate.
If the above problem is occurred, be sure to contact a service center to settle the problem.
Caution
Caution
If the fan in a set does not operate or has a problem, a fan error message pops up in the live
screen as below picture. And the fan error icon
If it is, check the fan in the set. The icon at the top of left disappears automatically if the fan
recovers its operation.
Concerning occurrence of a fan error, if it is a long-term problem it will shorten the lifespan of
the product.
When a fan error occurs, we ask that you please contact the service center.
)
appears at the top of left .
Fan Information
A error occurs in the fan.
Refer to the manual.