Control units
(cont.)
– Operating condition
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (day temperature)
Note
The set room temperature for reduced mode (night temperature)
is set at the control unit.
– Operating program
■ Party and economy mode can be enabled via keys
■ Integral room temperature sensor for room temperature hook-up
(only for one heating circuit with mixer)
Installation location:
■ Weather-compensated mode:
Installation anywhere in the building.
■ Room temperature hook-up:
The integral room temperature sensor captures the actual room
temperature and effects any necessary correction of the flow tem-
perature.
The captured room temperature depends on the installation site:
– Main living room on an internal wall opposite radiators.
– Not on shelves or in recesses.
– Never in the immediate vicinity of doors or close to heat sources
(e.g. direct sunlight, fireplace, TV set, etc.).
Note
Observe the "Wireless accessories" technical guide.
Vitotrol 300 RF with table-top dock
Part no. Z011 410
Wireless subscriber.
■ Displays:
– Room temperature
– Outside temperature
– Operating condition
– Graphic illustration of solar yield in conjunction with the solar con-
trol module, type SM1
– Wireless signal reception quality
■ Settings:
– Set room temperature for standard mode (day temperature) and
reduced mode (night temperature)
– Set DHW temperature
– Operating program, switching times for heating circuits, DHW
heating and DHW circulation pump plus further settings via plain
text menu on the display
– Party and economy mode can be enabled via keys
■ Integral room temperature sensor
Note
Observe the "Wireless accessories" technical guide.
Standard delivery:
■ Vitotrol 300 RF
■ Table-top dock
■ Plug-in power supply unit
■ Two rechargeable NiMH batteries for operating outside the table-top
dock
VITODENS
1 4
8
Specification
Power supply via 2 AA batteries 3 V
Radio frequency
Wireless range
Safety category
IP rating
Permissible ambient temperature
– During operation
– During storage and transport
Setting range of the set room tempera-
ture for standard mode
1 4
3
2 2
Vitotrol 300 RF
1 4
0
5 0
Table-top dock
868.3 MHz
See "Wireless accesso-
ries" technical guide
III
IP 30 to EN 60529
Ensure through design/in-
stallation
0 to +40 °C
−20 to +65 °C
3 to 37 °C
7