Pre-Installation With The Sub-Mounting Kit With Mixer – Installation On Finished Walls - Viessmann VITODENS 300-W Technical Manual

Vitodens series gas condensing boiler
Hide thumbs Also See for VITODENS 300-W:
Table of Contents

Advertisement

Design information
(cont.)
A
Showing pre-plumbing jig for Vitodens 200-W
A
Vitodens
B
Pre-plumbing jig
C
Area for power cables.
Allow all cables to protrude approx. 800 mm from the wall.
D
Compulsory in conjunction with DHW cylinders below the
boiler. Otherwise recommendation only.
E
Drain
GA
Gas connection Rp ½
Pre-installation with the sub-mounting kit with mixer – installation on finished walls
Required accessories:
■ Sub-mounting kit:
With plate heat exchanger, circulation pump, 3-way mixer, bypass,
mixer electronics, flow temperature sensor, cover and installation
template
■ Pre-plumbing jig:
With fixing components, valves and gas shut-off valve Rp ½ with
integral thermally activated safety shut-off valve
■ Connection set for DHW cylinders (if installed)
Not in conjunction with the Vitocell 100-W DHW cylinder installed
below the boiler.
VITODENS
B
C
SVL/WW
SRL/KW
E
HR
GA
HV
O K
F F
HR
Heating return Rp ¾
HV
Heating flow Rp ¾
KW
Cold water Rp ½ (gas combi boiler)
OKFF Top edge, finished floor
WW
DHW Rp ½ (gas combi boiler)
SRL
Cylinder return G ¾ (gas boiler)
SVL
Cylinder flow G ¾ (gas boiler)
For specification and accessories for the sub-mounting kit, see
page 43.
Install a drain & fill valve on site in the flow of the heating circuit with
mixer (HV2).