Specification - Viessmann VITODENS 300-W Technical Manual

Vitodens series gas condensing boiler
Hide thumbs Also See for VITODENS 300-W:
Table of Contents

Advertisement

Vitodens 300-W

3.2 Specification

Gas boiler, types B and C, category II
Rated heating output range (to EN 677)
T
/T
= 50/30 °C
F
R
T
/T
= 80/60 °C
F
R
Rated heating output for DHW heating
Rated heat input
Product ID
IP rating
Gas supply pressure
Natural gas
LPG
Max. permissible gas supply pressure
Natural gas
LPG
3
Power consumption
(in the delivered condition)
Weight
Heat exchanger content
Max. flow rate
(limit for the use of hydraulic separation)
Nominal circulation water volume
at T
/T
= 80/60 °C
F
R
Diaphragm expansion vessel
Capacity
Pre-charge pressure
Permiss. operating pressure
Safety valve connection
Dimensions
Length
Width
Height
Height with flue bend
Height with DHW cylinder below the boiler
Gas connection
Connection values
Relative to the max. load
with gas
Natural gas E
Natural gas LL
LPG P
*2
Flue gas parameters
Flue gas category to G 635/G 636
Temperature (at a return temperature of 30 °C)
– at rated heating output
– at partial load
Temperature (at a return temperature of 60 °C)
Mass flow rate
Natural gas
– at rated heating output
– at partial load
LPG
– at rated heating output
– at partial load
Available draught
*7
If the gas supply pressure is higher than the maximum permissible value, install a separate gas pressure governor upstream of the system.
*2
Calculation values for sizing the flue system to EN 13384.
Flue gas temperatures as actual gross values at 20 °C combustion air temperature.
The flue gas temperature at a return temperature of 30 °C is significant for the sizing of the flue system.
The flue gas temperature at a return temperature of 60 °C is used to determine the application range of flue pipes with maximum permissible
operating temperatures.
VIESMANN
22
(cont.)
2N3P
kW
kW
kW
kW
mbar
kPa
mbar
kPa
*7
mbar
kPa
mbar
kPa
W
kg
l
l/h
l/h
l
bar
kPa
bar
MPa
Rp
mm
mm
mm
mm
mm
R
m
3
/h
m
3
/h
kg/h
°C
°C
°C
kg/h
kg/h
kg/h
kg/h
Pa
mbar
Gas condensing boiler
1.9 - 11.0
1.9 - 19.0
1.7 - 10.1
1.7 - 17.2
1.7 - 16.0
1.7 - 17.2
1.8 - 16.7
1.8 - 17.9
CE-0085CM0463
IP X4D to EN 60529
20
20
2
2
50
50
5
5
25.0
25.0
2.5
2.5
57.5
57.5
5.75
5.75
35
58
50
50
3.8
3.8
1000
1200
434
739
10
10
0.75
0.75
75
75
3
3
0.3
0.3
¾
¾
360
360
450
450
850
850
1053
1053
1925
1925
½
½
1.77
1.89
2.05
2.20
1.31
1.40
G
/G
G
/G
52
51
52
51
45
45
35
35
68
68
29.7
31.8
3.2
3.2
28.2
30.3
3.0
3.0
250
250
2.5
2.5
4.0 - 26.0
4.0 - 35.0
3.6 - 23.7
3.6 - 31.7
3.6 - 23.7
3.6 - 31.7
3.8 - 24.7
3.8 - 33.3
20
20
2
2
50
50
5
5
25.0
25.0
2.5
2.5
57.5
57.5
5.75
5.75
76
122
48
50
5.6
5.6
1400
1600
1018
1376
3
3
0.3
0.3
¾
¾
380
380
480
480
850
850
1066
1066
1925
1925
½
½
2.61
3.52
3.04
4.10
1.93
2.60
G
/G
G
/G
52
51
52
51
45
45
35
35
70
70
43.9
59.2
6.8
6.8
41.7
56.3
6.4
6.4
250
250
2.5
2.5
VITODENS