Scanning Sequence Examples
In most cases scanning one bar code sets the parameter value. For example, to disable the decode aiming pattern,
scan the Disable Decode Aiming Pattern bar code listed under
scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Imaging Preferences Parameter Defaults
Table 5-1
lists the defaults for imaging preferences parameters. There are two ways to change the default values:
•
Scan the appropriate bar codes in this guide. These new values replace the standard default values in
memory. To recall the default parameter values, scan the
•
Download data through the device's serial port using SSI. Hexadecimal parameter numbers appear in this
chapter below the parameter title, and options appear in parenthesis beneath the accompanying bar codes.
Refer to the Simple Serial Interface (SSI) Programmer's Guide for detailed instructions for changing
parameters using this method.
NOTE See
miscellaneous default parameters.
Imaging Preferences Default Table
Table 5-1
Decoding Options
Focus Mode
Decoding Illumination
Decode Aiming Pattern
DPM Scanning
Low Light Enhancement
Presentation Mode Field of View
Image Capture Autoexposure
Image Capture Illumination
Appendix A, Standard Default Parameters
Parameter
Decode Aiming Pattern on page
*Restore Defaults
for all user preferences, hosts, symbologies, and
Parameter
Number
F0h A6h
Far Focus
Note: The default value
for DS3407-DP (DPM)
digital scanners is Near
Focus.
F0h 2Ah
Enable
F0h 32h
Enable
F1h 09h
Enable
F1h 64h
Disable
F1h 61h
Default (Reduced)
F0h 68h
Enable
F0h 69h
Enable
5-6. The digital
bar code on
page
4-4.
Page
Default
Number
5-5
5-6
5-6
5-7
5-8
5-8
5-9
5-9