Preparation And Positioning The Roof Top Unit - Carrier Air Conditioner Owner's Manual

Hide thumbs Also See for Air Conditioner:
Table of Contents

Advertisement

ALLOWABLE OFFSET FOR CARRIER AIR CONDITIONERS

PREPARATION AND POSITIONING THE ROOF TOP UNIT

1
The roof top air conditioner must be mounted on a level
plane from front to rear and side to side when the ve-
hicle is parked on a level plane. Figure 4 shows maxi-
mum allowable degrees that the Air V can be mounted
above or below level.
If the roof of the vehicle is sloped (not level) such that
the roof top air conditioner cannot be mounted within
the maximum allowable degree specifications, an ex-
terior leveling shim will need to be added to make the
Air V level. A typical leveling shim is shown in Figure 5.
2
Prepare the roof top unit for installation with the ceiling
assembly.
3
Install foam basepan pad at this time. See Figure 6. Pad
is provided with adhesive on one side with release paper.
4
Reach up into return air opening of the air conditioner
and pull the unit electrical cord down for later
connection.
NOTE
Above Level 10° Max.
Below Level 0° Max.
WITH CARLYLE ROTARY COMPRESSORS
AIR CONDITIONER DIMENSIONS (Roof Top Unit)
10.3"
14" x 14"
OPENING
41"
Above or Below
Level 10° Max.
16.7"
REAR OF
UNIT
'
OWNER
S GUIDE -
13
Figure 4
* Height Varies
To Make Unit
Level
Figure 5