Installation Instructions; Step 1. Selecting An Installation Location; Installing The Roof Top Heat Pump Unit - Carrier Air V Owner's Manual

Recreational vehicle air conditioner, heat pump unit for non ducted system
Hide thumbs Also See for Air V:
Table of Contents

Advertisement

3
During extreme outdoor temperatures, the heat
gain of the vehicle may be reduced by:
- parking the vehicle in a shaded area
- keeping the windows and doors closed
- avoiding the use of heat producing appliances
- using window shades (binds and/or curtains)
For a more permanent solution to reduce the high
heat gain, window awnings and/or window glass
tinting should be considered.

INSTALLATION INSTRUCTIONS

BEFORE INSTALLATION
Test run the unit with proper power supply outlet. Refer to the Operating Instructions section in this Owner's Guide.
Make sure all the controls operate correctly then disconnect the power supply of the unit.
Moving parts can cause personal injury. Be careful when test-running the unit.
Do not operate the unit with exterior cover removed.
STEP 1 - SELECTING AN INSTALLATION LOCATION &

INSTALLING THE ROOF TOP HEAT PUMP UNIT

Your Air V unit has been designed for use in recreational vehicles.
Check the roof of the vehicle to determine if it supports both the roof top unit and the ceiling assembly without
additional support. Make sure the interior ceiling mounting area will not interfere with existing structures.
Once the location for your air conditioner has been determined, a reinforced and framed roof hole opening must
be cut (if there is no hole) or you may use existing vent holes.
CASE A.
If a roof vent is already present in the desired mounting location for the air conditioner, the following steps must be
performed:
1
Remove all screws which secure
the roof vent to the vehicle.
Remove the vent and any
additional trim. Carefully remove
all chalking from around the
opening so the surface is clear.
4
When using the heating system the heat loss of the
vehicle may be reduced by:
- parking the vehicle in a sunny area
- keeping the windows and doors closed
- avoiding the use of heat absorbing appliances
WARNING
2
It may be necessary to seal
some of the old roof vent
mounting screw holes which
may fall outside of the air
conditioner basepan gasket.
OWNER
3
Examine the roof opening size. If
the opening is smaller than 14"
14", the opening must be
enlarged. If the opening
exceeds 14" 14", a mounting
p l a t e ( f r a m e ) m u s t b e
fabricated to reduce the
opening size (See Figure 1).
'
6
S GUIDE -

Hide quick links:

Advertisement

Table of Contents
loading