Installing The Remote Switch - Montigo H38DF Installation Operation & Maintenance

Gas fireplace
Table of Contents

Advertisement

Installing Terminations with Built-In Frames
11
11
1.
Frame the termination opening to 11" x 11".
2.
Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MSR Frames
12
12
1. Frame the termination opening to 12" x 12".
2. Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MOSR Frames
MOSR
PTO-3
1.
Frame the termination opening to 12" x 12".
2.
Fasten the MOSR frame to the interior side of the studs using a
minimum of 4 screws.
3.
Insert the termination into the MOSR frame as shown here, and
attach by screwing through the four pilot holes in the termination.
Part No. XG0131
Installation
Installing Heat Guards over Terminations
PTO-3F
1.
2.
MSR
To avoid elevated mantel temperatures, all H38DF gas fireplaces
are required to have the supplied standoffs and nailing flange
extention installed.
The fireplace is supplied with two standoffs. Bend and install these
standoffs on top of the fireplace ensuring that the height of the standoff
maintains a 6" clearance.
PTO-3
Figure 6b. Installing the standoff's.
Once the fireplace is placed into the framed opening, the supplied nailing
extention must placed along the top edge of the fireplace, and nailed in
place to the framing, as illustrated below.
12 12
12
Figure 6c. Installing the Nailing Flange Extension.
The H38DF's gas valve, located behind the lower trim, may be con-
nected to a wall switch. The valve generates its own power on a
millivolt circuit. Use only low voltage wire, and DO NOT connect
any external power to it.
Refer to Figure 30 for wiring requirements.
Note: The switch location must not exceed 30' from the fireplace.
Ensure that the two long mounting brackets are facing the bottom of
the termination. (See inset). This will provide more heat protection at
the top of the termination, where temperatures are highest.
Attach to the faceplate of the termination using four sheet metal screws.
Installing The Standoffs And
Nailing Flange Extention

Installing The Remote Switch