Clearance To Combustibles - Lopi Cape Cod Quick Manual

Hide thumbs Also See for Cape Cod:

Advertisement

Cape Cod Wood Stove Specifications
2"
(51mm)
19-3/4"
(501mm)
6" Flue
Diameter
EPA Phase II
Approved
Efficiency**
0.45
80.1% Avg.
Grams/Hour
* Heating capacity may vary depending on degree of home insulation, floor plan and ambient temperature zone of the area you live.
** Efficiency Tested to CSA B415.1-10, using the high heating value (HHV) for the test fuel. Avg. = Average of "All Burn Rates"

Clearance To Combustibles

Refer to the Owner's Manual for additional details.
Straight Wall
B
D
E
E
F
Single
Wall Pipe
A - Stove Top to Side Wall
12-3/4" (324mm)
B - Stove Top to Back Wall
14-3/4" (375mm)
C - Connector to Side Wall
26" (660mm)
D -Connector to Back Wall
15" (381mm)
E - Floor Protection Side/Back
6" US (8"-203mm CAN)
F - Floor Protection Front
16" US (18" - 457mm CAN)
www.lopistoves.com
Manufactured in
Mukilteo, WA
32-1/4"
(821mm)
35
(889mm)
Heating Capacity
Up to 2,500 Sq. Ft.* (232 M
)
2
Up to 3,000 Sq. Ft. with fan
C
A
Double
Wall Pipe
12-3/4" (324mm)
11-3/4" (375mm)
26" (660mm)
12" (305mm)
Your Lopi Authorized Dealer:
Lopi reserves the right to alter or improve its products at any time without notification. All trademarks belong to Travis Industries.
Always refer to the Owner's Manual for installation requirements!
Installation
We suggest that you have an authorized Lopi dealer install your stove. If you
install the stove yourself, your authorized dealer should review your installa-
tion plans. If this appliance is not properly installed, a house fire may result. For
your safety, follow the installation directions. Contact local building or fire of-
ficials about restrictions and installation inspection requirements in your area.
Child Safety
If you have small children or even pets, we highly recommend you consider pur-
chasing a safety screen or guard to prevent the possibility of burns resulting from
accidental contact with the hot surfaces of the stove. Ask your Lopi dealer for their
recommendations on safety options for your particular installation.
Testing
Tested and listed by Intertek Laboratories Inc. Conforms to UL STD 1482 and to
ULC S627-2000 .
3.0
Accepts 24" Wood
Up To 12 Hour
Cubic Foot
Firebox
Burn Time
Corner Wall
H
G
E
F
G - Stove Top to Corner
H - Connector to Corner Wall
Floor Protection
Non combustible floor protection must be at least .018" (.45mm) thick (26 gauge).
Minimum hearth size: Depth 41-3/4" US 39-3/4" CAN
video tour
or register
online for a
For installation specifications refer to the Owner's Manual found on the Lopi website.
Huge Fire View
Maximum BTUs
20-3/4" w x 13" H
(Cord Wood)
244 sq. inches
86,000 Per Hour
Alcove
Combustible Alcove
Maximum Depth of Alcove
48" (1220mm)
Minimum Width of Alcove
59" (1499mm)
E
Minimum Height of Alcove
84" (2134mm) above top of stove
Non-Combustible Alcove
Maximum Depth of Alcove
48" (1220mm)
Minimum Width of Alcove
50" (1270mm)
Minimum Height of Alcove
6" (152mm) above top of stove
Single
Double
Wall Pipe
Wall Pipe
7-1/4" (184mm)
7-1/4" (184mm)
17-1/2" (445mm)
17" (432mm)
Width 44-1/4" US 48-1/4" CAN
Take the
plant tour
in person.
©2012/09 Printed in U.S.A. - #98800547