Stove Installation

Alcove Installation Requirements

Whenever the stove is placed in a location where the ceiling height is less than 7' (2134mm) tall, it is
considered an alcove installation. Because of the reduced height, the special installation requirements
listed below must be met.
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have walls
and a ceiling that are 3 1/2" (89mm) thick of a non-combustible material (brick, stone, or concrete -
see Figure 7). This non-combustible material must be spaced and ventilated at least 1" (25mm) off of
all combustible materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls
and ceiling. All other alcoves are considered combustible. The clearances below must be met:

Minimum Clearance

(See the Figure 7 below)
A
Sidewall to stove
B
Back-wall to stove
D
Connector to sidewall
E
Connector to back-wall
G
Maximum depth of alcove
H
Minimum width of alcove
J
Minimum height of alcove
Non-combustible alcove
construction (on walls
and ceiling) - see the
explanation above.
Ventilated
air space
1" (25mm)
Min.
© Travis Industries
Combustible Alcove 
13"
4-1/4" 108mm
21-1/2"
6-1/2" 165mm
48"
54"
84"
Min. 3 1/2"
(89mm) non-
combustible
material
Non-combustible
reinforcer
(for qualified installers only)
330mm
546mm
1219mm
1372mm
2134mm
100-01334
Non‐Combustible Alcove 
6"
152mm
2"
51mm
14-1/2"
368mm
4-1/4" 108mm
48"
1219mm
36"
914mm
6" (152mm) above stove top
13
Figure 7
4131122

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

LopiEndeavor nd