Safety

Important Regulatory and Safety Requirements

H Operation
Before operating the boiler, make sure you fully
understand its method of operation. Your heating
contractor should always perform the initial start-up and
explain the system.
Any warranty is null and void if these instructions are not
followed.
H Working on the equipment
All personnel working on the equipment or the heating
system must have the proper qualifications and hold all
necessary licenses.
Ensure main power to equipment, heating system, and
all external controls has been deactivated. Close main oil
or gas shut-off valve. Take precautions in all instances to
avoid accidental activation of power during service work.
H Dangerous conditions
– Deactivate main power immediately.
– Close main gas or oil shut-off valve.
H Gas smell
Follow the instructions on the front page of this manual.
H Flue gas smell
– Deactivate heating equipment.
– Open windows and doors.
– Inform your heating contractor.
CAUTION
Incomplete combustion and poisonous gases result if
the fresh air intakes in the mechanical room are closed.
Never close these openings.
H Combustion air and ventilation air openings
Ensure that combustion air openings and ventilation air
openings in the mechanical room are open.
H Technical information
Literature applicable to the Vitorond
200, VD2 / VD2A series boiler:
– Installation Instructions
– Service Instructions
– Operating Instructions and User's Information Manual
– Installation codes mentioned in this manual
IMPORTANT
Keep all literature in a safe place at the installation site.
Contact Viessmann for additional copies.
4
Vitorond 200, VD2/VD2A Series Operating
H Regular maintenance and service
The entire heating system must be cleaned and serviced
on a regular basis by a qualified heating contractor or
service agency to ensure reliable, energy-efficient, and
environmentally friendly operation.
The build-up of soot on the heat exchanger raises the
flue gas temperature and reduces efficiency.
Indirect-fired domestic hot water storage tanks (if
installed) must be serviced within two years (at most) of
the installation date, and regularly thereafter (see Service
Schedule starting on page 11).
For an overview of scheduled service procedures, please
see section entitled "Service Schedule" on page 11 of
this manual.
WARNING
The boiler must not be located in areas or rooms
where chemicals are stored, or aggressive vapors
from (i.e. bleach, hair spray, methyl chloride, carbon
tetrachloride or perchloroethylene) or high dust
levels or humidity levels are present. Heat exchanger
corrosion might occur and reduce the lifetime of the
boiler significantly. If above criteria are not properly
observed and boiler damage results, any warranty
on the complete boiler and related components will
be null and void.
IMPORTANT
Keep boiler and boiler room clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation air.
All inspection, maintenance and service must be performed
by a qualified heating contractor.
WARNING
Improper installation, adjustment, service, or
maintenance can cause flue products to flow into
living space. Flue products contain poisonous carbon
monoxide gas which can cause nausea or asphyxiation
resulting in severe personal injury or loss of life.
WARNING
As there are no user-serviceable parts on the boiler,
burners or control, the end-user must not perform
service activities of any kind on system components.
Failure to heed this warning can cause property
damage, severe personal injury, or loss of life.