Panasonic WV-SC385 Installation Manual page 18

Hide thumbs Also See for WV-SC385:
Table of Contents

Advertisement

Guide part
Lock plate
Moving part
Camera
Important:
• When mounting the camera onto the camera mount
bracket, hold the base part of the camera. Mounting
the camera while holding the moving part may result
in malfunction.
Step 7
Fix the camera on the camera mount bracket (accessory)
using the camera fixing screw (accessory).
Recommended tightening torque: 0.68 N·m
{0.50 lbf·ft}
Fixing screw
(accessory)
18
Center of the
camera mount bracket
Base part
Camera mount bracket
(accessory)
Step 8
Connect the cables to the network connector and the
power inlet.
Important:
• When the power of the camera is turned on, the cam-
era will start panning and the position will automati-
cally be initialized.
• Do not touch the camera in the process of initializa-
tion. Otherwise, it may fail to initialize and may cause
malfunction.
• When the camera has been inadvertently touched
and moved after the initialization is complete, the pre-
set positions may be inaccurate. In this case, use the
position refresh function or restart the camera to cor-
rect the preset positions.
Refer to the Operating Instructions (included in the
CD-ROM) for further information.
Network connector
12 V DC power supply terminal
10BASE-T/
100BASE-TX
POWER
LINK
ACT
INITIAL
SET
12V IN
• Network connector
Connect a LAN cable (category 5 or better, STP*) to the
network connector.
* For Europe
Important:
• Use all 4 pairs (8 pins) of the LAN cable.
• The maximum cable length is 100 m {328 feet}.
• Make sure that the PoE device in use is compliant
with IEEE802.3af standard.
• When connecting both the 12 V DC power supply
and the PoE device for power supply, 12 V DC will be
used for power supply.
Depending on the PoE device used, the power supply
lamp may not light and the network connections may
not be possible. In this case, disable the PoE device
setting, and refer to the operating instructions of the
PoE device in use.
• When the LAN cable is disconnected once, reconnect
the cable after around 2 seconds. When the cable is
quickly reconnected, the power may not be supplied
from the PoE device.
EXT I/O
MIC/LINE IN
AUDIO OUT
MONITOR OUT
4 3 2 1