H1 Quick Test Mode; H1 Description Of Error Codes - Maytag AGS1740BD series Service

Gas slide-in range
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
H1 (AGS5830BD*, MGS5775BD*, MGS5875BD*) "Quick Test" Mode for
Electronic Range Control
Follow the procedure below to perform the quick test. Instructions must be entered within 32 seconds of each other
(via the touch pad) or the ERC will exit the quick test.
1. Press and hold the Cancel and Broil pads for 5 seconds at power-up, or within 5 minutes of power-up.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press each of the following pads indicated in the table below.
NOTE:
Press and hold the applicable pad to activate the associated response.
Release the applicable pad to deactivate the associated response.
Display will indicate the following:
Pad
BAKE ................................... Bake DLB and Bake relay activated.
BROIL.................................. Broil DLB and Broil relay activated.
KEEP WARM....................... Bake DLB and Broil DLB activated.
CONVECT BAKE ................ Convection fan activated.
CONVECT ROAST ............. Convection fan activated, cooling fan activated.
CLEAN................................. Motorized door lock activated.
COOK & HOLD ................... Displays last diagnostic code.
FAVORITE........................... Displays EEPROM version number.
TIMER ................................. Displays main code version number.
CLOCK ................................ All display segments illuminated.
OVEN LIGHT....................... Oven light activated.
CANCEL .............................. Exits the test mode.
0........................................... N/A
1........................................... Even segments on.
2........................................... Odd segments on.
3........................................... Convection Ring activated; Convection Ring DLB activated.
4........................................... Bake Relay activated.
5........................................... Broil Relay activated.
6........................................... Convection Relay activated.
7........................................... N/A
8........................................... N/A
9........................................... N/A
AUTOSET............................ Steps through last 5 diagnosis codes.
H1 (AGS5830BD*, MGS5775BD*, MGS5875BD*) Description of Error Codes
Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode.
Each error code is four digits long and created based on the following table.
Digit
st
1
nd
2
rd
3
th
4
Diagnostic Code Display Mode can be activated by pressing and holding the Autoset pad for 5 seconds at
power-up. Diagnostic Code Display Mode can only be started while powering up the control.
24
!
Response
Primary System:
1 – Local to the control circuit board
3 – Sensor or meat probe
4 – Control input
9 – Door lock
Measurable:
d – Diagnostic: measurable parameter
c – Control related, replace control
Secondary System: Sequential numbering
Oven Cavity:
1 – Upper oven (or single cavity oven)
2 – Lower oven
c – Control specific
WARNING
Description
16026293
©2005 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading