Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.

Component Testing Procedures

Illustration
Oven light socket
Door plunger switch
Autolatch assembly
270° valve
Spark 270° switch
Spark ignition
electrode
Top surface burner
Top surface burner cap
Spark module 4 + 0
L
A
B
N
A1
B1
Temperature sensor
Broil burner
Bake burner
Ignitor
Convection element
14
!
Component
Test continuity of receptacle terminals....
Measure voltage at oven light.................
Remove switch from unit and measure
the following points:
COM to NO ........................................ Plunger in continuity, plunger out infinity.
Disconnect wires and test for
continuity per wiring diagram.
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
Verify gas is supplied.
5 K btu
9.2 K btu
Adjust set screw for simmer control.
12.5 K btu
16 K btu
Test for voltage at terminals ..................
Disconnect wiring and check for
continuity in LITE position......................
Test for resistance of spark lead............
Test ignitor to chassis............................
Verify gas is supplied.............................
5 K btu
Verify burner cap is positioned
9.2 K btu
correctly.
12.5 K btu
16 K btu
Verify cap is positioned correctly ........... Check for obstructions in burner ports.
Test for voltage at terminals L and N .....
Check polarity and ground.....................
Measure resistance ............................... Approximately 1000 Ω at room
Verify gas is supplied.
Orifice adjusted for Natural or LP ..........
Check for obstructions or
contamination in ports ...........................
Verify gas is supplied.
Orifice adjusted for Natural or LP ..........
Check for obstructions or
contamination in ports ...........................
Test for voltage at terminals ..................
Test for amperage in the circuit .............
(Ignitor may glow but not have
sufficient amperage to open valve.)
Disconnect wiring to element and
measure resistance of terminals............
Measure voltage at broil element...........
WARNING
Test Procedure
16026293
Results
Indicates continuity with bulb screwed in.
120 VAC; see wiring diagram for terminal
identification. If no voltage is present at
oven light check wiring.
See wiring diagram for schematic layout.
Access assembly by removing right side
panel.
Common is in neutral position unless
locking or unlocking autolatch assembly.
120 VAC
Continuity in LITE position.
Continuity
No continuity from ignitor to chassis.
Check for obstructions in burner ports.
120 VAC (tolerance: 102 to 132 VAC)
See wiring diagram
temperature 75° F (23.8° C).
Factory set to Natural Gas.
Adjust as necessary.
Air shutter opening set to .281 to .343.
Replace if punctured or torn.
Factory set to Natural Gas.
Adjust as necessary.
Air shutter opening set to .469 to .531.
Replace if punctured or torn.
120 VAC.
3.2 − 3.6 Amps. If not, replace.
Approximately 30 Ω.
240 VAC.
©2005 Maytag Services