Electric Slide-In Range⎯Technical Information
AES1350BA*
• Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
• Refer to Service Manual 16026299 for detailed installation, operating, testing, troubleshooting, and disassembly
instructions.
All safety information must be followed as provided in Service Manual 16026299.
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
Model
Power Source @ 240 V (208 V)
Electrical rating
Amperage rating
Frequency
Element Wattage @ 240 V**
Coil, 6
", 3-turn (AES1350BA*) (2 ea)
Coil, 8
", 4-turn (AES1350BA*) (2 ea)
Coil, 6
", 4-turn (AES3540BA*, MES5552BA*) (2 ea)
Coil, 8
", 5-turn (AES3540BA*, MES5552BA*) (2 ea)
Oven Wattage @ 240 V (208 V)**
Bake
Broil
Oven Interior Dimensions in. (cm)
Height
Width
Depth
Product Exterior Dimensions in. (cm)
Height Overall
Width
Depth oven door closed, excl. handle
Depth oven door closed, incl. handle
Features
Electronic controls
Child lockout
Sabbath mode
Self-cleaning oven
Removable storage drawer
Electronic ignition
8
-pass
broiler
Delay start
Timer
Large oven window
Standard oven window
Optional backsplash
Weight lbs. (kg)
Approximate shipping weight
**Rating of 208 VAC is approximately 80% of 240 VAC value.
May 2005
©2005 Maytag Services
AES3540BA*
!
CAUTION
!
WARNING
AES1350BA*
9.7 (7.3) Kw
50 Amp
60 Hz
1250
(940)
1575
(2100)
N/A
N/A
2400
(1900)
3000
(2250)
16 1/2
(41.9)
23
(58.4)
18 1/8
(46)
35 3/4
(90.8)
29 7/8
(75.9)
26 3/16 (66.5)
28 3/16 (71.6)
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
171
(77.6)
1
MES5552BA*
AES3540BA*
MES5552BA*
11.3 (8.5) Kw
11.3 (8.5) Kw
50 Amp
50 Amp
60 Hz
60 Hz
N/A
N/A
N/A
N/A
1500
(1130)
1500
2350
(1765)
2350
2400
(1900)
2400
3600
(2700)
3600
16 1/2
(41.9)
16 1/2
23
(58.4)
23
18 1/8
(46)
18 1/8
35 3/4
(90.8)
35 3/4
29 7/8
(75.9)
29 7/8
26 3/16 (66.5)
26 3/16 (66.5)
28 3/16 (71.6)
28 3/16 (71.6)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
171
(77.6)
171
(1130)
(1765)
(1900)
(2700)
(41.9)
(58.4)
(46)
(90.8)
(75.9)
(77.6)
16026294

Advertisement

loading

Summary of Contents for Maytag AES1350BA

  • Page 1 50 Amp 50 Amp 50 Amp Frequency 60 Hz 60 Hz 60 Hz Element Wattage @ 240 V** Coil, 6 ", 3-turn (AES1350BA*) (2 ea) 1250 (940) Coil, 8 1575 (2100) ", 4-turn (AES1350BA*) (2 ea) Coil, 6 1500 (1130)
  • Page 2: Component Testing Procedures

    Coil element, Disconnect wiring to element and Approx. 42.5 to 50 Ω 1250 W, 3-turn measure cold resistance of terminals..Model AES1350BA* Measure voltage at element ....240 VAC Coil element, Disconnect wiring to element and Approx. 43 to 49 Ω...
  • Page 3: Oven Control Testing Procedures

    This mode disables the normal 12 hour Desired bake function must be shutoff to allow operation of the bake initiated before entering Sabbath mode. mode for a maximum of 72 hours. The oven light is not disabled. May 2005 16026294 ©2005 Maytag Services...
  • Page 4: "Quick Test" Mode For Electronic Range Control

    [Clean] Beep sounds [Delay] (M1) EEPROM Version Number displayed [Timer] Main Code Version Number displayed [Clock] All Segments On [More +] Even Segments On [Less –] Odd Segments On [Cancel] End Factory Test Mode 16026294 May 2005 ©2005 Maytag Services...
  • Page 5 Disables Clean and Lockout functions 4, 5 4d51 Door switch not open or closed Disables Clean/Lockout functions Nothing Turn off light, disable light at door switch 9d11 Lock switch not closed LOCK flashes Disables Clean and Lockout functions May 2005 16026294 ©2005 Maytag Services...
  • Page 6 • The control will not fault. • If a function requiring latch movement is attempted while the lock switch is faulted, the control will sound an error tone and the function will be disabled. 16026294 May 2005 ©2005 Maytag Services...
  • Page 7: Wiring Diagram And Schematic

    Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Model AES1350BA* Wiring Diagram May 2005 16026294 ©2005 Maytag Services...
  • Page 8 Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Model AES1350BA* Control Circuits 16026294 May 2005 ©2005 Maytag Services...
  • Page 9 Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Models AES3540BA*, MES5552BA* Wiring Diagram May 2005 16026294 ©2005 Maytag Services...
  • Page 10 Wiring Diagram and Schematic WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Models AES3540BA*, MES5552BA* Control Circuits 16026294 May 2005 ©2005 Maytag Services...

This manual is also suitable for:

Aes3540baMes5552ba