M1 Quick Test Mode - Maytag AGS1740BD series Service

Gas slide-in range
Table of Contents

Advertisement

Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to range before servicing,
unless testing requires power and/or gas.
Control
Component
M1 Controlled
Sabbath Mode
M1 Controlled
Child lock out
M1 Controlled
Diagnostic Code
Display
M1 (AGS1740BD*, MGS5752BD*) "Quick Test" Mode for Electronic Range
Control
Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the
control will exit the quick test mode.
1. Press and hold CANCEL and BROIL pads for 5 seconds.
2. Once the control has entered the "Quick Test" mode, release both pads.
3. Press each of the following pads indicated in the table below.
NOTE: First time one of the following pads is pressed, it activates the response.
The second time the pad is pressed, it deactivates the response.
NOTE: This mode can only be entered within the first 5 minutes of power up.
NOTE: If the temperature sensor is greater than 400° F or if the temperature sensor reaches 400° F while
under test, the Quick Test mode will be disabled.
Display will indicate the following:
[Bake]
[Broil]
[Keep Warm]
[Cook&Hold]
[Clean]
[Delay] (M1)
[Timer]
[Clock]
[Up Arrow]
[Down Arrow]
[Cancel]
16
!
Test Procedure
Hold CLOCK pad for 5 seconds to
activate Sabbath mode.
Hold CLOCK pad for 5 seconds to
disable Sabbath mode.
Desired bake function must be initiated
before entering Sabbath mode.
Press and hold CANCEL and COOK
& HOLD pads for 3 to 5 seconds until
beep sounds.
To reactivate the control, press and
hold CANCEL and COOK & HOLD
pads for 5 seconds.
Press and hold (Up Arrow) pad
within 60 seconds of powering up
the unit.
Cycle through the codes using the
(Up Arrow) or (Down Arrow) pads.
Key
Bake relay activated
Broil relay activated
DLB relay activated
Last Diagnostic Code displayed
Beep sounds
EEPROM Version Number displayed
Main Code Version Number displayed
All Segments On
Even Segments On
Odd Segments On
End Factory Test Mode
WARNING
"SAb" will flash for 5 seconds, then remain on until
timed-out or cancelled.
The status SAB is not fault code 5AB.
All pad inputs are disabled except for CANCEL and
CLOCK pads.
This mode disables the normal 12 hour shutoff to
allow operation of the bake mode for a maximum of
72 hours.
The oven light is not disabled.
This is a safety feature that can be used to prevent
children from accidentally programming the oven. It
disables the electronic oven control.
Child lockout features must be reset after a power
failure.
The last 5 diagnostic codes will be stored in the non-
volatile memory.
See
Description of Error Codes
"
Operation
16026293
Results
for explanation.
"
©2005 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents