Cycle Operation Mode Per Battery Type 25P - GRAUPNER Polaron EX Operating Instruction

2 ch dc charger
Hide thumbs Also See for Polaron EX:
Table of Contents

Advertisement

Charge mode selection in cycle mode
Discharge mode selection in cycle mode
Charge mode and start delay time is programmed. Tap the box to
activate in blue and tap DEC/INC button to select the desired mode.
Discharge modes are explained below
The charger initiates to discharge after down counting and
when to tap Enter button,
charge immediately
Start delay time
1~150 minutes can be set.
The charger initiates the cycle charge/discharge after the
lapse of the preset time.
Cycle operation mode per battery type
Cycle charge discharge mode of POLARON EX
LiPo, LiIon, LiFe, Pb
CC-CV
NORMAL : Normal discharge mode
LINEAR
NiCd, NiMH
AUTO
NORMAL : Normal charge/discharge
LINEAR
This page shows the process of battery check when the
balancer is connected. The next page is accessed
automatically When to tap Enter button
initiates to charge immediately
Battery Cell Checking
25
the charger initiates to
: Normal charge mode
: The preset current is maintained throughout the
discharge.
: The charge will automatically adjust the
charge/discharge condition
: The preset current is maintained throughout the
chage/discharge.
the charger
Number of cells checking
When to connect balance board, the charger can only
check the number of cells. If the confirmed number of cells
is not correct, tap ESC button to get back to the previous
page and check the parameters again. If the number of
cells is correct, the next page is accessed automatically.
When to be initiated without balance board, it is activated
for you to check and decide the number of cells. When to
tap Enter button,
the charger initiates to charge
immediately
This page shows the cycle process with parameters and graph.
Voltage and current will reach to the preset parameters.
The preset current might have limitation depending on
charge/discharge capacity and input voltage setup. Max charge is
400W and max discharging is 60W
Cycle operating screen
The operating indicator blinks on the top
The number of operating cycle is shown
When to tap graph, the operating data is shown
When to tap the part in red circle, Set current window
appears and, you may change the charge/discharge current
during operating and set current window disappears when to
tap X button.
This setup is applied to the charger that is operating and it
is not stored to memory