Imaging Test Pattern 0; Imaging Test Pattern 1 - AGFA QCR-Z Operator's Manual

Table of Contents

Advertisement

Operator Instructions

Imaging Test Pattern 0

Load film into the camera module and prepare the module for an exposure
(advance film to frame #1, remove dark slide, etc.) To select test pattern 0,
press and hold the TEST switch down so that you hear the QCR-Z's audio
alarm beep twice. When this occurs, the QCR-Z will image test pattern 0 onto
the film.
If you wish to view the the test pattern as it scans on the QCR-Z's CRT,
power off the QCR-Z and remove the module. Power the film recorder on and
wait for its warmup routine to finish. Press the TEST switch down so that you
hear the QCR-Z's audio alarm beep once, then release the TEST switch. The
QCR-Z will not care whether the camera module is installed, and it will begin
scanning the test pattern line-by-line on the CRT. If you hold the TEST switch
down for two beeps with no module installed, the QCR-Z will indicate a module
fault and terminate the test sequence.

Imaging Test Pattern 1

To select test pattern 1, press and hold the TEST switch up so that you hear
the QCR-Z's audio alarm beep twice. When this occurs, the QCR-Z will image
test pattern 1 onto the film. The same conditions apply as for test pattern 0; if
you wish to view the test pattern on the CRT, press the TEST switch up so that
you hear the QCR-Z's audio alarm beep once.
QCR-Z Operator's Guide Version 4
4-16