I MENU mode items (Continued)
D External Input Level "AUX LEVEL"
Set the external input level.
• OFF (0)
: The external input does not operate.
• 001–080 : Setting the external input level from 1 to 80.
• AF GAIN : Interlocking with [VOL].
D Beep Tone Level "BEEP"
Confirmation beep tones normally sound when storing mem-
ory, operating time-out-timer function, etc. These can be set
the desired beep level as you prefer.
• OFF (0)
: The beep tone turns OFF.
• 001–100 : Setting the beep tone level from 1 to 100.
NOTE:
When using an external speaker, the beep tone level when
the squelch is closed is fixed and cannot be changed in the
MENU mode.
D Intercom Usable Setting "INCOM MODE"
Set the intercom using or not.
• ON
: The intercom is usable.
• OFF
: The intercom is unusable.
D Time-Out-Timer "TIME OUT"
To prevent accidental prolonged transmission, etc., the trans-
ceiver has a time-out-timer function. This timer starts when a
transmission begins, and will cut off the transmission when
the time set in the timer elapses.
• 020–240 : Setting time-out-timer starting period from 20 sec. to
240 sec. at 10 sec. intervals.
D Frequency Step "FREQ. STEP"
Set the desired frequency step: 8.33 kHz or 25 kHz.
• 25kHz
: Setting the frequency step to 25 kHz.
• 8.33kHz
: Setting the frequency step to 8.33 kHz.
D Memory Clear "MEM CLEAR"
Setting values in the CPU are cleared.
Push and hold [MEM] for 2 sec., the CPU is reset as follow.
• MENU
: MENU mode items are reset.
• MEMORY
: Stored memories are reset.
• ALL
: All CPU data is reset.
5
MENU MODE
05
25

Advertisement

Table of Contents