Connecting Power; Control Via Rs-485 Interface; Wdr True Day&Night Camera - Genie GSDNR-5355W Instruction Manual

Wdr true day&night camera
Table of Contents

Advertisement

¡á Installation Procedures

Connecting Power

Since power specifications differ, depending on the model, make sure to check
the model name and exact specification before connecting power.
Connect power as shown in the following figure.
Low Voltage AC / DC Power
• Check the standard power requirement before connecting to power.
Dual Power Type
(AC 24V/DC 12V, AC 24V Class2)
DC Power Type (DC 12V, 500mA)
When the resistance value of copper wire is at [20¢ª C(68¢ª F)]
Copper wire size(AWG)
#24(0.22mm
Resistance value( /m)
0.078
Voltage drop(V/m)
0.028
• As shown in the table above, voltage decreases as the wire gets longer.
Therefore use of an excessively long adaptor output line for connection to
the camera may affect the performance of the camera.
¡ØStandard voltage for camera operation : DC 12V¡¾ 10%, AC 24V¡¾ 10%
¡ØThere may be some deviation in voltage drop depending on the type of wire
and the manufacturer.
18
WDR True Day&Night Camera
AC90~240V-50Hz/60Hz 4.5W
AC90~240V~
50Hz/60Hz 4.5W
)
#22(0.33mm
)
#20(0.52mm
)
#18(0.83mm
2
2
2
0.050
0.030
0.018
0.018
0.011
0.006
Control via the RS-485 Interface
The camera can be controlled by using an external controller equipped with
RS-485 communications.
• To control using a DVR or keyboard controller
Connect the RS-485 cable (TRX+, TRX-) to the connection port of the 485
control board in the DVR or controller.
485 Control Board Connection Port
(+) CONNECTION TERMINAL (TRX+)
(- ) CONNECTION TERMINAL (TRX-)
* RS-485 communication default initial values
Item
Initial value
Note
• To control the camera use Pelco-D protocol.
(Go Preset 95 : Enters into OSD menu or Set key function)
)
2
RS-485 Control Port
Camera ID
BAUD RATE
UART MODE
1
9600
8-NONE-1
19
WDR True Day&Night Camera
485+
485-
PET PKT
ENABLE

Advertisement

Table of Contents
loading

Table of Contents